IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 92
Table 5-29: Swift-Lift/Ultra-Lift Parameter Settings
NOTE:
C06-11 through C06-16 are hidden unless C06-10 = 0 “Custom”.
Parameter
Display
Function
Range
Default
C06-01
Swift-Lift (V/f and OLV)
Ultra-Lift (FLV)
Determines if Swift/Ultra-Lift is enabled.
0–4
0
0 Disabled
1 Enabled Auto
2 Enabled by MFDI
3 Enabled Adaptive
Flux Vector NLB only
4 Adaptive by MFDI
Flux Vector NLB only
C06-02
SwiftLift FWDSpd
UltraLift FWDSpd
Maximum Swift/Ultra-Lift Forward Speed
0.1–150.0 Hz
60.0
C06-03
SwiftLift REVSpd
UltraLift REVSpd
Maximum Swift/Ultra-Lift Reverse Speed
0.1–150.0 Hz
60.0
C06-04
SL FWD Current (V/f)
SL FWD Torque (OLV)
UL FWD Torque (FLV)
Output Current/Torque < C06-04 to enable
Swift/Ultra-Lift Forward. Not used with Adaptive
UL.
0–100%
50
C06-05
SL REV Current (V/f)
SL REV Torque (OLV)
UL REV Torque (FLV)
Output Current/Torque < C06-05 to enable
Swift/Ultra-Lift Reverse. Not used with Adaptive
UL.
0–100%
30
C06-06
SL Enabling Spd
UL Enabling Spd
Frequency at which to trigger Swift/Ultra-Lift.
0.1–150.0 Hz
59.0
C06-07
SL Delay Time
UL Delay Time
Delay time at Enabling speed to check Output
Current/Torque
0.0–25.5 sec
2.0
C06-08
SFS Acc Gain
Acceleration multiplier for V/f Modes. Greater
than 1 increases accel time; less than 1
decreases accel time.
0.1–9.9
1.0
C06-10
Mtr Trq Quickset
Available motor torque over base speed.
0–5
3
0 Custom
1 Very Low Torque
2 Low Torque
3 Standard
4 High Torque
5 Very High Torque
C06-11
Motor Torque 1
Available torque at Speed 1 (above base speed)
1–100%
45
C06-12
Motor Speed 1
Speed 1 point
100–300%
150
C06-13
Motor Torque 2
Available torque at Speed 2 (above base speed)
1–100%
25
C06-14
Motor Speed 2
Speed 2 point
100–300%
200
C06-15
AUL FWD Offset
Adaptive UL torque measurement offset in the
up direction to allow for deceleration.
0–100%
10
C06-16
AUL REV Offset
Adaptive UL torque measurement offset in the
down direction to allow for deceleration
0–100%
20