Table of Functions
95
*O: Write-
enabled during operation, Δ: Write-enabled when operation stops, X: Write-
disabled
Code
(Comm.
Address)
Name
LCD
Display
Setting Range
Initial Value
Property* Ref.
IN-00
(-)
Jump Code
Jump
Code
1-99
65
O
IN-01
(0h1501)
Frequency at
maximum
analog input
Freq at
100%
Start frequency-
Maximum frequency
(Hz)
Maximum
frequency
O
IN-05
22
(0h1505)
V1 input
voltage display
V1
Monitor(V)
-
0.00
X
IN-06
(0h1506)
V1 input
polarity
selection
V1
Polarity
0
Unipolar
0:
Unipolar
Δ
1
Bipolar
IN-07
(0h1507)
Time constant
of V1 input
filter
V1 Filter
0
–10000 (ms)
10
O
IN-08
(0h1508)
V1 minimum
input voltage
V1 Volt x1 0.00-10.00 (V)
0.00
O
IN-09
(0h1509)
Output at V1
minimum
voltage (%)
V1 Perc
y1
0.00-100.00 (%)
0.00
O
IN-10
(0h150A)
V1 maximum
input voltage
(%)
V1 Volt x2 0.00-12.00 (V)
10.00
O
IN-11
(0h150B)
Output at V1
maximum
voltage (%)
V1 Perc
y2
0.00-100.00 (%)
100.00
O
IN-12
23
(0h150C)
V1 input at
minimum
voltage (%)
V1
–Volt
x1”
-10.00- 0.00 (V)
0.00
O
IN-13
(0h150D)
Output at V1
minimum
voltage (%)
V1
–Perc
y1”
-100.00-0.00 (%)
0.00
O
22
“IN-05” setting range can be changed according to the “IN-06” settings.
23
IN-12
–17 are displayed when IN-06 is set to “1 (Bipolar)”.
Summary of Contents for H100 0008-2(PLUS)
Page 26: ......
Page 30: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Page 31: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Page 32: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Page 33: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Page 34: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Page 35: ...Preparing the Installation 9 500 kW 3 Phase ...
Page 46: ...Installing the Inverter 20 200 V 0 75 18 5kW 400 V 0 75 185kW 400 V 220 500kW ...
Page 48: ...Installing the Inverter 22 ...
Page 63: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Page 207: ...Technical Specification 181 6 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Page 208: ...Technical Specification 182 110 185 kW 3 phase 220 500 kW 3 phase ...
Page 237: ...211 목차 EN IEC 61800 3 2018 EN 61800 5 1 2007 A1 2017 ...
Page 238: ...212 ...
Page 239: ...213 목차 ...