Table of Functions
77
Code
(Comm.
Address)
Name
LCD
Display
Setting Range
Initial value
Property* Ref.
23
160.0kW(250.0HP)
24
185.0kW(300.0HP)
25
220.0kW(350.0HP)
26
250.0kW(400.0HP)
27
315.0kW(500.0HP)
28
355.0kW(550.0HP)
29
400.0kW(650.0HP)
30
500.0kW(800.0HP)
DRV-15
(0h110F)
Torque
boost
options
Torque
Boost
0
Manual
0: Manual
Δ
1
Auto 1
2
Auto 2
DRV-16
2
(0h1110)
Forward
Torque
boost
Fwd Boost 0.0
–15.0 (%)
2.0
0.75~
90kW
Δ
1.0
110~
500kW
DRV-17
(0h1111)
Reverse
Torque
boost
Rev Boost
0.0
–15.0 (%)
2.0
0.75~
90kW
Δ
1.0
110~
500kW
DRV-18
(0h1112)
Base
frequency
Base Freq
30.00
–400.00 (Hz)
60.00
Δ
DRV-19
(0h1113)
Start
frequency
Start Freq
0.01
–10.00 (Hz)
0.50
Δ
DRV-20
(0h1114)
Maximum
frequency
Max Freq
40.00-400.00 (Hz)
60.00
Δ
DRV-21
(0h1115)
Select
speed unit
Hz/Rpm
Sel
0
Hz Display
0: Hz Display
O
1
RPM Display
2
DRV-16
–17 are displayed when DRV-15 is set to “0 (Manual)”.
Summary of Contents for H100 0008-2(PLUS)
Page 26: ......
Page 30: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Page 31: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Page 32: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Page 33: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Page 34: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Page 35: ...Preparing the Installation 9 500 kW 3 Phase ...
Page 46: ...Installing the Inverter 20 200 V 0 75 18 5kW 400 V 0 75 185kW 400 V 220 500kW ...
Page 48: ...Installing the Inverter 22 ...
Page 63: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Page 207: ...Technical Specification 181 6 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Page 208: ...Technical Specification 182 110 185 kW 3 phase 220 500 kW 3 phase ...
Page 237: ...211 목차 EN IEC 61800 3 2018 EN 61800 5 1 2007 A1 2017 ...
Page 238: ...212 ...
Page 239: ...213 목차 ...