Appendix
Code table
371
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0108
Gain for relative analog signals
(AOUT)
1 FCODE(gain)
100.0
−199.99
{0.01 %}
199.99 FCODE_nC108_1_a
2 FCODE(gain)
100.0
FCODE_nC108_2_a
C0109
Offset for relative analog signals
(AOUT)
1 FCODE(offset)
0.0
−199.99
{0.01 %}
199.99 FCODE_nC109_1_a
2 FCODE(offset)
0.0
FCODE_nC109_2_a
C0110 Service Code
Fine adjustment − mutual
inductance
50
{1 %}
200
C0111 Service Code
Fine adjustment − rotor
resistance
50.00
{1 %}
199.99
C0112 Service Code
Fine adjustment − rotor time
constant
50
{1 %}
200
C0113 Service Code
Fine adjustment − magnetising
current (I
sd
)
50
{1 %}
200
C0114
Polarity of the digital inputs
1 DIGIN pol
0
HIGH level active
X6/DI1 (DIGIN_bIn1_b)
2 DIGIN pol
0
HIGH level active
X6/DI2 (DIGIN_bIn2_b)
3 DIGIN pol
0
HIGH level active
X6/DI3 (DIGIN_bIn3_b)
4 DIGIN pol
0
HIGH level active
X6/DI4 (DIGIN_bIn4_b)
0
HIGH level active
1
LOW level active
C0118
Polarity of the digital outputs
1 DIGOUT pol
0
HIGH level active
X6/DO1 (DIGOUT_bOut1_b)
2 DIGOUT pol
0
HIGH level active
X25 (DIGOUT_bRelais_b, brake
connection)
0
HIGH level active
1
LOW level active
C0120 OC6 limit
105
Threshold for I
2
x t monitoring
(motor)
0
{1 %}
120 0 = I
2
x t monitoring is switched
off
I
2
x t > C0120
ð
OC6−TRIP
C0121 OH7 limit
120
Threshold for motor temperature
monitoring
45
{1
°
C}
150 Motor temperature > C0121
ð
fault message OH7 (C0584)
C0122 OH4 limit
80
Threshold for heatsink
temperature monitoring
45
{1
°
C}
90 Heatsink temperature
> C0122
ð
fault message OH4
(C0582)
C0123 OC7 limit
90
Threshold for I x t warning (axis
module)
0
{1 %}
100 C0064 > C0123
ð
fault message
OC7 (C0604)