Appendix
Code table
13
363
EDBCSXS064 EN 4.0
13
Appendix
13.1
Code table
How to read the code table
Column
Abbreviation
Meaning
No.
Cxxxx
Code no. Cxxxx
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
Cxxxx
Changed input value of the code or subcode is accepted after pressing
.
[Cxxxx]
Changed input value of the code or subcode is accepted after pressing
when the controller is inhibited.
Name
LCD display of the keypad XT EMZ9371BC
Lenze/{Appl.}
x
Lenze setting:
l
Value at the time of delivery or after loading the Lenze setting using
C0002.
{xxx...}
Different application initialisation value
l
Value at the time of delivery
l
After loading the Lenze setting using C0002, the application
initialisation value is overwritten with the Lenze setting.
l
The application initialisation values can be restored by loading the
application software with "Global Drive Loader" (GDL).
à
The "Important" column contains further information
Selection
1
{%}
99 minimum value
{unit} maximum value
IMPORTANT
Short code description
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0002 Par load
0
Load parameter set
The Lenze setting can only be
loaded if the controller is
inhibited (CINH).
0
Load Lenze setting
Load Lenze setting into the RAM
and activate it.
Only possible if C2108 = 2 (PLC
stopped).
1
Load parameter set 1
Load parameter set 1 into the
RAM and activate it.
Parameter set 1 is loaded
automatically after every mains
connection.
C0003 Par save
0
Non−volatile saving of parameter
set
0
No response
1
Save parameter set
C0004 Op display
56
Selection of XT keypad status
display
1
{Code no.}
9999 The keypad displays the selected
code in the operating level, if no
status messages from C0183 are
active (e. g.: 56 = torque setpoint
(C0056))