Commissioning
Setting of the feedback system for position and speed control
Absolute value encoder as position encoder and resolver as speed encoder
120
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0419] Enc. setup
110
Encoder selection
l
Selection of encoder type
indicated on the nameplate of
the Lenze motor.
l
The encoder data (C0420,
C0421, C0427) is set
automatically in accordance
with the selection.
0
Common
110
IT512−5V
Incremental encoder with TTL
level
111
IT1024−5V
112
IT2048−5V
113
IT4096−5V
210
IS512−5V
SinCos encoder
211
IS1024−5V
212
IS2048−5V
213
IS4096−5V
307
AS64−8V
SinCos absolute value encoder
with Hiperface® interface
(single−turn)
Selections 307, 308, 309 are only
possible with operating system
7.0 or higher.
308
AS128−8V
309
AS256−8V
310
AS512−8V
311
AS1024−8V
407
AM64−8V
SinCos absolute value encoder
with Hiperface® interface
(multi−turn)
Selections 407, 408, 409 are only
possible with operating system
7.0 or higher.
408
AM128−8V
409
AM256−8V
410
AM512−8V
411
AM1024−8V
[C0420] Encoder const.
512
Number of increments of the
encoder
1
{1 inc/rev}
8192 Sets C0419 = 0 ("common") if the
value is altered.
[C0421] Encoder volt
0
Encoder voltage
0
5.0 V
Sets C0419 = 0 ("common") if the
value is altered.
1
5.6 V
2
6.3 V
3
6.9 V
4
7.5 V
5
8.1 V
[C0427] Enc. signal
0
Function of the master frequency
input signals on X8 (DFIN)
0
2−phase
1
A: speed
B: direction
2
A or B: speed or direction
[C0491] X8 in/out
0
Function of X8
0
X8 is input
1
X8 is output