C0070 Vp speedCTRL
3.0
Proportional gain of speed
controller (V
pn
)
0.00
{ 0.01}
127.99
C0071 Tn speedCTRL
24.0
Reset time − speed controller
(T
nn
)
1.0
{0.5 ms}
6000.0
C0072 Td speedCTRL
0.0
Derivative gain of speed
controller (T
dn
)
0.0
{0.1 ms}
32.0
C0074 Dynamics
0
Pilot control of the current
controller for higher dynamics
0
Normal
1
Enhanced
C0075 Vp currCTRL
20.0
Proportional gain of current
controller (V
pi
)
The upper limit is
device−dependent.
0.00
{0.01
W
}
381.80 ECSxS/P/M/A004
190.90 ECSxS/P/M/A008
95.46 ECSxS/P/M/A016
47.72 ECSxS/P/M/A032
31.82 ECSxS/P/M/A048
23.86 ECSxS/P/M/A064
C0076 Tn currCTRL
5.0
Reset time of current controller
(T
ni
)
0.01
{0.01 ms}
200.00
C0077 Vp fieldCTRL
5.0
Field controller gain (V
pF
)
0.00
{0.01}
63.99
C0078 Tn fieldCTRL
20.0
Field controller reset time (T
nF
)
1.0
{0.5 ms}
6000.0
C0079 DIS:Lh
Mutual inductance of the
asynchronous motor
Read only
0.0
{0.1 mH}
3276.7
[C0080] Res pole no.
1
Number of pole pairs of resolver
1
{1}
10
[C0081] Mot power
3.20
Rated motor power according to
nameplate
0.01
{0.01 kW}
500.00
[C0082] DIS:Rr
Rotor resistance of the
asynchronous motor
Read only
0.000
{0.001
W
}
32.767
C0083 DIS:Tr
Rotor time constant of the
asynchronous motor
Read only
0.00
{0.01 ms}
327.67