Commissioning
Operation with motors from other manufacturers
Effecting rotor position adjustment
151
EDBCSXS064 EN 4.0
6.15.4
Effecting rotor position adjustment
Note!
Resolver / absolute value encoder with Hiperface® interface
ƒ
If the rotor zero phase is not known, the rotor position only has to be
adjusted once during commissioning.
ƒ
For multi−turn absolute value encoders, the traversing range must be within
the display range of the encoder (0 ... 4095 revolutions) if the traversing
range is limited.
TTL incremental encoder / sin/cos encoder with zero track
ƒ
If these encoder types are used for the operation of synchronous motors, the
rotor position must be adjusted every time the low−voltage supply is
switched on.
The rotor position must be adjusted if:
ƒ
A motor from another manufacturer is connected to the controller.
ƒ
Another encoder has been mounted subsequently.
ƒ
A defective encoder has been replaced.
The rotor position can only be adjusted if:
ƒ
The resolver is polarised correctly.
ƒ
The current controller has been adjusted.
The GDC contains the parameters or codes to be set on the parameter menu under
Motor/Feedb.
Rotor position adjustment
:
ECSXA304
Fig. 6−21
GDC view: Short setup of the feedback system