Appendix
Code table
409
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C2493
Process data output words
(decimal) for CAN bus interface
X14
100.00% = 16384
Read only
1 CANa OUT
words
−199.99
{0.01 %}
199.99 CANaux1_OUT word 1
2 CANa OUT
words
CANaux1_OUT word 2
3 CANa OUT
words
CANaux1_OUT word 3
4 CANa OUT
words
CANaux2_OUT word 1
5 CANa OUT
words
CANaux2_OUT word 2
6 CANa OUT
words
CANaux2_OUT word 3
7 CANa OUT
words
CANaux2_OUT word 4
8 CANa OUT
words
CANaux3_OUT word 1
9 CANa OUT
words
CANaux3_OUT word 2
10 CANa OUT
words
CANaux3_OUT word 3
11 CANa OUT
words
CANaux3_OUT word 4
C2500
PLC flag 1 ... 255
0
{1}
65535
C2501
PLC flag 256 ... 512
0
{1}
65535
C3005 ControlMode
0
Selection of operating modes
0
Common
Display with changed standard
application
100
None
Reset of all signal connections
1000
SpeedTerm
Speed−controlled, setpoint via
analog input
1003
SpeedAIF
Speed−controlled, setpoint via
AIF
1005
SpeedCAN
Speed−controlled, setpoint via
MotionBus (CAN)
4000
TorqueTerm
Torque−controlled, setpoint via
analog input
4003
TorqueAIF
Torque−controlled, setpoint via
AIF
4005
TorqueCAN
Torque−controlled, setpoint via
MotionBus (CAN)
C3998 BuildNo
Build no. of the application
software
Read only
C3999 Version
Version of the application
software
Read only