Appendix
Code table
408
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C2485 MONIT CE15
3
Fault response − gate function
monitoring (CE15)
"Timeout" when remote
parameterisation (C0370) is
activated via interface X14
(CAN−AUX)
0
TRIP
2
Warning
3
Off
C2491
Process data input words
(hexadecimal) for CAN bus
interface X14
Hexadecimal value is bit−coded.
Read only
1 CANa IN bits
0
{1 hex}
FFFF CANaux1_IN (bit 0 ... 15)
2 CANa IN bits
CANaux1_IN (bit 16 ... 31)
3 CANa IN bits
CANaux2_IN (bit 0 ... 15)
4 CANa IN bits
CANaux2_IN (bit 16 ... 31)
5 CANa IN bits
CANaux3_IN (bit 0 ... 15)
6 CANa IN bits
CANaux3_IN (bit 16 ... 31)
C2492
Process data input words
(decimal) for CAN bus interface
X14
100.00% = 16384
Read only
1 CANa IN
words
−199.99
{0.01 %}
199.99 CANaux1_IN word 1
2 CANa IN
words
CANaux1_IN word 2
3 CANa IN
words
CANaux1_IN word 3
4 CANa IN
words
CANaux2_IN word 1
5 CANa IN
words
CANaux2_IN word 2
6 CANa IN
words
CANaux2_IN word 3
7 CANa IN
words
CANaux2_IN word 4
8 CANa IN
words
CANaux3_IN word 1
9 CANa IN
words
CANaux3_IN word 2
10 CANa IN
words
CANaux3_IN word 3
11 CANa IN
words
CANaux3_IN word 4