Mechanical installation
Mounting in cold−plate design
46
EDBCSXS064 EN 4.0
4.4
Mounting in cold−plate design
The axis modules ECSC... are intended for mounting in cold−plate design (e.g. on collective
coolers).
Requirements for collective coolers
The following requirements must be met to ensure a safe operation of the axis modules:
ƒ
Good thermal contact with the cooler
– The contact surface between collective cooler and axis module must be at least as
large as the cooling plate of the axis module.
– Smooth contact surface, max. deviation 0.05 mm.
– Connect the collective cooler with all specified screwed connections to the axis
module.
ƒ
Maintain the thermal resistance R
th
according to the table.
– The values apply for operating the axis modules under rated conditions.
Axis module
Power to be dissipated
Heat sink − environment
Type
Ploss [W]
R
th
[k/W]
ECSC
004
14.0
0,31
ECSC
008
29.0
ECSC
016
64.0
ECSC
032
117.0
0,13
ECSC
048
132.0
ECSC
064
158.0
0,11
Application software:
S = Speed & Torque
P = Posi & Shaft
M = Motion
A = Application
ƒ
Ambient conditions:
– Furthermore the rated data regarding the ambient temperature and the derating
factors at increased temperature apply to the axis modules (
– Temperature of the cooling plate ("Cold Plate"): max. +85 °C