Commissioning
Quick stop (QSP)
144
EDBCSXS064 EN 4.0
6.14
Quick stop (QSP)
By means of the quick stop function, the drive is braked to standstill within a set
deceleration time (C0105).
Quick stop (QSP) is activated by the following signal sources:
Configuration/operating mode
QSP active if
Lenze setting
During mains connection
l
X6/DI1 and DI2 = HIGH
or
l
X6/DI1 and DI2 = LOW
During operation
l
X6/DI1 and DI2 = LOW
QSP is recognised device−internally if a LOW signal is
applied to X6/DI1 and DI2 for more than 2 ms.
Speed control ("Speed")
l
SPEED−QSP.Set1 (C7411/17) = TRUE
or
l
SPEED−QSP.Set2 (C7411/18) = TRUE
(further information:
Torque control ("Torque"):
l
TORQUE−QSP.Set1 (C7511/17) = TRUE
or
l
TORQUE−QSP.Set2 (C7511/18) = TRUE
(further information:
The deceleration time for the brake application is set via C0105 in the GDC parameter
menu under
ƒ
Short setup
Speed
(for speed control).
ƒ
Short setup
Torque
(for torque control).
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0042 DIS: QSP
Quick stop status (QSP)
Only display
144
0
QSP not active
1
QSP active
C0105 QSP Tif
0.0
Deceleration time for quick stop
(QSP)
144
0.000
{0.001 s}
999.999 Relating to speed variation n
max
(C0011) ...0 rev./min.