Troubleshooting and fault elimination
Fault messages
Causes and remedies
244
EDBCSXS064 EN 4.0
Remedy
Cause
Description
Fault message
Remedy
Cause
Description
Display
No.
1131
PRM
Parameters of the motor model
are faulty
The parameters calculated from
the entered rated motor data are
outside the permissible value
range.
Check and correct the set rated
motor data (especially C0084,
C0085, C0088, C0090).
x190
nErr
Speed control error
(Speed out of tolerance margin
(C0576))
l
Active load (e.g. for hoists) is
too high.
l
Mechanical blockades on the
load side
Check drive dimensioning.
x191
HSF
Internal error
Contact Lenze.
x200
NMAX
Maximum system speed (C0596)
has been exceeded.
l
Active load (e.g. for hoists) is
too high.
l
Drive is not speed−controlled,
torque is excessively limited.
l
Check drive dimensioning.
l
Increase torque limit, if
necessary.
l
Switch off monitoring
(C0607 = 3).
0201
overrun
Task1
Time−out in task 1 (ID 2)
Task processing takes longer than
the monitoring time set.
l
Adjust the length of the task
runtime.
l
Adjust monitoring time.
l
Determine the cause of
time−out by checking the task
runtime at the task monitor.
l
Swap out time−critical program
parts in a slower task.
...
...
...
0208
overrun
Task8
Time−out in task 8 (ID 9)
0209
float
Sys−T
Float error in system task (ID 0)
Error in real calculation
(e. g. division by 0)
Check calculations (program
code).
0210
float
Cycl.−T
Float error in cyclic task (PLC_PRG
ID 1)
0211
float Task1
Float error in task 1 (ID 2)
...
...
...
0218
float Task8
Float error in task 8 (ID 9)
0219
overrun
Cyc.−T
Time−out in cyclic task (PLC_PRG
ID 1)
Task processing takes longer than
the monitoring time set.
l
Adjust the length of the task
runtime.
l
Adjust monitoring time.
l
Determine the cause of
time−out by checking the task
runtime at the task monitor.
l
Swap out time−critical program
parts in a slower task.
0220
noT−Fkt
Credit
Not enough technology units
available.
A program with technology
functions has been tried to be
loaded to a controller not
providing the corresponding
units.
l
Use technology variant of the
controller.
l
Contact Lenze, if necessary.
0230
No
Program
Missing PLC program
No PLC program loaded.
Load PLC program.
0231
Unallowed
Lib
PLC program calls invalid library
function.
In the PLC program a library
function has been called which is
not supported by the controller
(e.g. because the corresponding
hardware is missing).
l
Remove library function or
ensure that the corresponding
hardware is available.
l
Contact Lenze, if necessary.
0232
NoCam
Data
Motion profiles (cam data) are not
available.
When calling functions of the
function library
LenzeCamControl.lib
it was
detected that there are no motion
profiles (CAM data) loaded in the
memory of the controller.
l
Ensure that the valid cam data
has been attached to the
project via the DDS CAM
support.
l
Reload the PLC program into
the controller. (Possibly the
command
Online
Reset
(origin)
has been executed in
DDS.)
x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP