Commissioning
Operation with motors from other manufacturers
Entering motor data manually
147
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0111 Service Code
Fine adjustment − rotor
resistance
50.00
{1 %}
199.99
C0112 Service Code
Fine adjustment − rotor time
constant
50
{1 %}
200
C0113 Service Code
Fine adjustment − magnetising
current (I
sd
)
50
{1 %}
200
C0128 Tau motor
5.0
Thermal time constant of the
motor
0.5
{0.1 min}
25.0 For calculating the I
2
x t
disconnection
[C0418] Test Cur.Ctrl
0
Controller adjustment:
0
Deactivated
Deactivate test mode
1
Activated
Activate test mode