Appendix
Code table
373
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0134 RFG charac
0
Characteristic of the ramp
function generator for the
l
speed setpoint (for "speed
control")
l
torque setpoint (for "torque
control")
1
Linear
Ramp function generator
operates linearly.
2
S−shaped
Ramp function generator
operates without jerk (S−shaped).
C0135 Control word
0
System control word DCTRL
0
{1}
65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0
Not assigned
Bit 1
Not assigned
Bit 2
Not assigned
Bit 3
Quick stop (QSP)
Bit 4
Not assigned
Bit 5
Not assigned
Bit 6
Not assigned
Bit 7
Not assigned
Bit 8
Operation inhibit (DISABLE)
Bit 9
Controller inhibit (CINH)
Bit 10
TRIP−SET
Bit 11
TRIP−RESET
Bit 12
Not assigned
Bit 13
Not assigned
Bit 14
Not assigned
Bit 15
Not assigned
C0136
Control words
Hexadecimal value is bit−coded.
Read only
1 CTRLWORD
0
{hex}
FFFF Control word C0135
2 CTRLWORD
CAN control word
3 CTRLWORD
AIF control word
C0141 FCODE(setval)
0.0
Main setpoint (FCODE_C141_a)
−199.99
{0.01 %}
199.99
C0142 Start options
1
Starting condition for start after
l
mains connection
l
message (t > 0.5 s)
l
TRIP
0
Protection against unexpected start−up
1
Automatic start