Function library
AIF2Out
260
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C6155 AIF2PdoMap
0
Assignment of the 8 byte user
data of the AIF2Out function
block to the fieldbus module
0
W0=Int W1=Int
Byte 1, byte 2 = AIF2Out−W0
Byte 3, byte 4 = AIF2Out−W1
Byte 5, byte 6 = AIF2Out−W2
Byte 7, byte 8 = AIF2Out−W3
1
W0 / W1=Dint
Byte 1, byte 2 = AIF2Out−W0/W1
Byte 3, byte 4 = AIF2Out−W0/W1
Byte 5, byte 6 = AIF2Out−W2
Byte 7, byte 8 = AIF2Out−W3
User data
The eight bytes of user data to the fieldbus module can be assigned with
ƒ
analog signals (16 bits).
ƒ
phase signals (32 bits).
The switch C6155 is used to assign the eight bytes of user data to the fieldbus module:
Value in
C6155
User data
Byte 1, 2
Byte 3, 4
Byte 5, 6
Byte 7, 8
0
AIF2Out−W0
AIF2Out−W1
AIF2Out−W2
AIF2Out−W3
16 bits (C6131/5)
16 bits (C6131/6)
16 bits (C6131/7)
16 bits (C6131/8)
1
AIF1Out−W0/W1
AIF2Out−W2
AIF2Out−W3
32 bits (C6151/2)
16 bits (C6131/7)
16 bits (C6131/8)