Function library
CAN3In
289
EDBCSXS064 EN 4.0
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0863
Digital process data input words
for CAN bus interface X4
Hexadecimal value is bit−coded.
Read only
0000
{hex}
FFFF
1 CAN IN bits
Bit 0
...
Bit15 CAN1_IN: Process data input
word 1
2 CAN IN bits
Bit 16
...
Bit 31 CAN1_IN: Process data input
word 2
3 CAN IN bits
Bit 0
...
Bit15 CAN2_IN: Process data input
word 1
4 CAN IN bits
Bit 16
...
Bit 31 CAN2_IN: Process data input
word 2
5 CAN IN bits
Bit 0
...
Bit15 CAN3_IN: Process data input
word 1
6 CAN IN bits
Bit 16
...
Bit 31 CAN3_IN: Process data input
word 2
C0866
Analog process data input words
(decimal) for CAN bus interface
X4
100.00% = 16384
Read only
1 CAN IN words
−199.99
{0.01 %}
199.99 CAN1_IN word 1
2 CAN IN words
CAN1_IN word 2
3 CAN IN words
CAN1_IN word 3
4 CAN IN words
CAN2_IN word 1
5 CAN IN words
CAN2_IN word 2
6 CAN IN words
CAN2_IN word 3
7 CAN IN words
CAN2_IN word 4
8 CAN IN words
CAN3_IN word 1
9 CAN IN words
CAN3_IN word 2
10 CAN IN words
CAN3_IN word 3
11 CAN IN words
CAN3_IN word 4
C0867
32−bit phase information for
CAN bus interface X4
Read only
1 CAN IN phi
−2147483648
{1}
2147483647 CAN1_IN
2 CAN IN phi
CAN2_IN
3 CAN IN phi
CAN3_IN