Appendix
Code table
389
EDBCSXS064 EN 4.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0490] Feedback pos
0
Selection of feedback system for
positioning control
0
Resolver at X7
Standard setting
1
TTL encoder at X8
l
Sets C0419 = 0 ("Common") if
a different encoder type as
under C0419 is set here.
2
SinCos encoder at X8
3
Absolute value encoder (single−turn) at
X8
4
Absolute value encoder (multi−turn) at
X8
[C0491] X8 in/out
0
Function of X8
0
X8 is input
1
X8 is output
[C0495] Feedback n
0
Selection of feedback system for
speed control
0
Resolver at X7
Standard setting
1
TTL encoder at X8
l
Sets C0419 = 0 ("Common") if
a different encoder type as
under C0419 is set here.
2
SinCos encoder at X8
3
Absolute value encoder (single−turn) at
X8
4
Absolute value encoder (multi−turn) at
X8
C0497 Nact filter
2.0
Time constant of actual speed
value
0.0
{0.1 ms}
50.0 0.0 ms = switched off
C0504 Service codes
Only the Lenze service is allowed
to make changes!
...
C0509
C0510 ProtAppFlash
0
Write−protection application
FLASH
0
No write protection
1
Write protection is active
C0517
User menu with up to 32 entries
0.00
{0.01}
7999.00
l
Enter the numbers of the
required codes into the
subcodes.
Format: xxxx.yy
– xxxx = code number
– yy = subcode of the code
l
It is not checked whether the
entered code exists.
1 User menu
51.00
C0051
MCTRL−NACT
Display of actual speed
2 User menu
54.00
C0054
Imot
Display of motor current
3 User menu
56.00
C0056
MCTRL−MSET2
Display of torque setpoint
4 User menu
0.00
Not assigned
5 User menu
0.00
Not assigned
6 User menu
183.00
C0183
Diagnostics
Display for diagnostics
7 User menu
168.01
C0183
Fail number
Display of current fault message
8 User menu
0.00
Not assigned
9 User menu
22.00
C0022
Imax current
Input of maximum output
current