Function library
DigOut (freely assignable digital outputs)
308
EDBCSXS064 EN 4.0
12.21
DigOut (freely assignable digital outputs)
Function
This function block conditions the digital signal "DigOut−Out1" and outputs it via X6/DO1.
ƒ
A motor holding brake supplied with low voltage via X6/B+ and X6/B− can be
connected to X25/B1 and X25/B2 62
– The motor holding brake can be switched by the signal DigOut−Relay .
– The terminal polarity for the outputs X6/DO1, X25/B1 and X25/B2 can be
configured via C0118.
ƒ
X6/SO serves to return information concerning the safety function "safe torque off"
(
Out
p
uts
_
D
I
G
I
TAL
X
6
X
6
1
0
C0118
/
1
D
O
1
SO
1
B-
B
2
B
+
1
0
C0118
/
2
1
B
1
X25
X
6
safe
torque
off
C0
444/
1
C0
444/
2
C0602
M
O
N
IT-
Re
l
1
D
IGOUT_
b
O
ut1
_
b
D
IGOUT_
bRe
l
ais
_
b
ECSXA242
Fig. 12−22
DigOut function block
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0118
Polarity of the digital outputs
308
1 DIGOUT pol
0
HIGH level active
X6/DO1 (DIGOUT_bOut1_b)
2 DIGOUT pol
0
HIGH level active
X25 (DIGOUT_bRelais_b, brake
connection)
0
HIGH level active
1
LOW level active
C6370
Display of the output signals at
the digital output and the brake
relay
308
0 (= FALSE)
1 (= TRUE)
1 DIGOUT
Output signal at the digital
output X6/DO1 (DigOut−Out1)
2 DIGOUT
Control of the brake relay
(DigOut relay)
[C6371]
Selection of the digital output
signals for the digital output and
the brake relay
308
1 DigoutIn−dig
1000
0 (FALSE, not assigned)
Source for the output signal at
the digital output X6/DO1
(DigOut−Out1)
2 DigoutIn−dig
1000
0 (FALSE, not assigned)
Source for the control of the
brake relay (DigOut relay)
For possible signals see "selection list − digital
signals"