Function library
DigIn (freely assignable digital inputs)
307
EDBCSXS064 EN 4.0
12.20
DigIn (freely assignable digital inputs)
Function
This function block reads and conditions the signals on X6/DI1 ... DI4.
ƒ
The configuration of the terminal polarity for the inputs X6/DI1 ... DI4 is effected via
C0114.
ƒ
The "safe torque off" safety function (
71) is controlled via X6/SI1 and X6/SI2.
C0443
X6
DigIn
DI3
SI1
SI2
DI1
DI4
DI2
safe standstill
1
0
C0114/1...4
1
X6
C0443
132
133
134
135
131
136
m
P
m
P + Imp
DigIn-In1
DigIn-In2
DigIn-safe_standstill
DigIn-In4
DigIn-In3
DigIn-CInh
ECSXA241
Fig. 12−21
DigIn function block
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0114
Polarity of the digital inputs
307
1 DIGIN pol
0
HIGH level active
X6/DI1 (DIGIN_bIn1_b)
2 DIGIN pol
0
HIGH level active
X6/DI2 (DIGIN_bIn2_b)
3 DIGIN pol
0
HIGH level active
X6/DI3 (DIGIN_bIn3_b)
4 DIGIN pol
0
HIGH level active
X6/DI4 (DIGIN_bIn4_b)
0
HIGH level active
1
LOW level active
C0443 DIS: DIGIN
Signal status of the digital inputs
on X6 after consideration of the
polarity set under C0114.
Only display
307
0
{1}
255
Bit 0
DIGIN1
X6/DI1
Bit 1
DIGIN2
X6/DI2
Bit 2
DIGIN3
X6/DI3
Bit 3
DIGIN4
X6/DI4
Bit 4
DIGIN_safe_standstill
X6/SI2
0: Pulse inhibit is active
1: Pulse inhibit is inactive
Bit 5
Free
Bit 6
DIGIN_CInh
X6/SI1
0: Controller is inhibited (CINH)
1: Controller is enabled
Bit 7
Free