1. Locate the failing hot-swap redundant power supply on the rear of your server. Then, press the release
tab
1
in the direction as shown and carefully pull the handle
2
at the same time to slide the redundant
power supply out of the chassis.
Note:
Do not use too much strength. You can first carefully slide the redundant power supply a little bit
out to release it from the secured position. Then, completely slide it out of the chassis.
Figure 88. Removing a hot-swap redundant power supply
2. Touch the static-protective package that contains the new hot-swap redundant power supply to any
unpainted surface on the outside of the server. Then, remove the new hot-swap redundant power
supply from the package.
Chapter 6
.
Installing, removing, or replacing hardware
151