3. The non-hot-swap hard disk drives are installed in the lower hard-disk-drive cage and are protected
by an EMI-protective panel. Press the small tab
1
on the EMI-protective panel from the bottom and
then pivot the EMI-protective panel upward to remove it from the chassis and gain access to the
non-hot-swap hard-disk-drive bays.
CPU
MEM
PSU
CPU
MEM
PSU
1
2
Figure 75. Removing the EMI-protective panel
4. Remove the server cover. See “Removing the server cover” on page 87.
5. Remove the front system fan 1. See “Replacing the front system fan” on page 158.
6. Locate the appropriate non-hot-swap hard-disk-drive bay. See “Server components” on page 25.
7. Touch the static-protective package that contains the new non-hot-swap hard disk drive to any
unpainted surface on the outside of the server. Then, take the new non-hot-swap hard disk drive and
the signal cable out of the package.
Note:
Do not touch the circuit board on the hard disk drive.
Chapter 6
.
Installing, removing, or replacing hardware
139
Summary of Contents for ThinkServer TS430
Page 16: ...4 ThinkServer TS430 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS430 Hardware Maintenance Manual ...
Page 96: ...84 ThinkServer TS430 Hardware Maintenance Manual ...
Page 192: ...180 ThinkServer TS430 Hardware Maintenance Manual ...
Page 200: ...188 ThinkServer TS430 Hardware Maintenance Manual ...
Page 242: ...230 ThinkServer TS430 Hardware Maintenance Manual ...
Page 249: ...Appendix A Notices 237 ...
Page 250: ...238 ThinkServer TS430 Hardware Maintenance Manual ...
Page 262: ...250 ThinkServer TS430 Hardware Maintenance Manual ...
Page 263: ......
Page 264: ......