1U riser-card
assembly
ServeRAID adapter
Release pin
Attention:
Incomplete insertion might cause damage to the server or the adapter.
Step 9.
Connect any required cables to the ServeRAID adapter.
Attention:
• When you route cables, do not block any connectors or the ventilated space around any of
the fans.
• Make sure that cables are not routed on top of components that are under the PCI riser-card
assembly.
• Make sure that cables are not pinched by the server components.
Step 10. Rotate the retention latch to the closed position, making sure the retention latch engages the
ServeRAID adapter. Then, push in the release pin to lock the retention latch in place.
Step 11. Install PCI riser-card assembly 2 (see “Installing a PCI riser-card assembly” on page 89).
Step 12. Import your RAID configuration to the replacement ServeRAID adapter as
a foreign configuration. See the
ServeRAID-M Software User Guide
at
https://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=migr-5086126 for
instructions.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 87.
Notes:
1. When you restart the server for the first time after you install a ServeRAID adapter with a battery, the
monitor screen remains blank while the controller initializes the battery. This might take a few minutes,
after which the startup process continues. This is a one-time occurrence.
Important:
You must allow
the initialization process to be completed. If you do not, the battery pack will not work, and the server
might not start.
The battery comes partially charged, at 30% or less of capacity. Run the server for 4 to 6 hours to
fully charge the battery. The LED just above the battery on the controller remains lit until the battery
is fully charged.
Until the battery is fully charged, the controller firmware sets the controller cache to write-through mode;
after the battery is fully charged, the controller firmware re-enables write-back mode.
2. When you restart the server, you are given the opportunity to import the existing RAID configuration to
the new ServeRAID adapter.
62
Lenovo System x3630 M4 Installation and Service Guide
Summary of Contents for System x3630 M4
Page 1: ...Lenovo System x3630 M4 Installation and Service Guide Machine Type 7158 ...
Page 6: ...iv Lenovo System x3630 M4 Installation and Service Guide ...
Page 14: ...xii Lenovo System x3630 M4 Installation and Service Guide ...
Page 108: ...94 Lenovo System x3630 M4 Installation and Service Guide ...
Page 134: ...120 Lenovo System x3630 M4 Installation and Service Guide ...
Page 186: ...172 Lenovo System x3630 M4 Installation and Service Guide ...
Page 844: ...830 Lenovo System x3630 M4 Installation and Service Guide ...
Page 868: ...854 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1026: ...1012 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1030: ...1016 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1038: ...Taiwan BSMI RoHS declaration 1024 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1040: ...1026 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1049: ......
Page 1050: ......