Note:
When the ServeRAID adapter is removed, software RAID will not be supported. This system
does not support downgrade software RAID function from hardware RAID configuration.
Replacing a ServeRAID adapter on the PCI riser-card assembly
Use this information to replace a ServeRAID adapter on the PCI riser-card assembly.
To install a ServeRAID adapter on the PCI riser-card assembly, complete the following steps:
Notes:
• The ServeRAID M5120 adapter can only be installed in the slot 1, 2, 3 or 4 (with 2U riser).
• The IMM interface can display storage RAID information provided that your server has the following
hardware installed:
– One or two Intel Xeon E5-2600 V2 series processors
– One ServeRAID adapter in slot 3 or slot 5
Step 1.
Read the safety information that begins in “Safety” on page v and “Installation guidelines” on
page 36.
Step 2.
Turn off the server (see “Turning off the server” on page 26) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables from the server.
Step 3.
Remove the server top cover (see “Removing the server top cover” on page 320).
Step 4.
If you are installing a new or replacement ServeRAID adapter, touch the static-protective package
that contains the new ServeRAID adapter to any unpainted metal surface on the server. Then,
remove the ServeRAID adapter from the package.
Step 5.
If you are installing a new or replacement ServeRAID adapter that uses a battery, complete the
following steps:
1. Remove the battery from the ServeRAID adapter package or the battery package.
2. Install the battery and connect the battery to the ServeRAID controller as instructed in the
documentation that comes with the ServeRAID controller or the battery, or see “Installing a
ServeRAID adapter battery or flash power module in the remote battery tray” on page 63.
Step 6.
Pull the release pin to unlock the retention latch; then rotate the retention latch to the open position.
Step 7.
Align the ServeRAID adapter so that the keys align correctly with the connector on PCI riser-card
assembly 2.
Step 8.
Insert the ServeRAID adapter into the connector on the riser-card until it is firmly seated.
For 2U riser card:
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
Release
pin
2U riser-card
assembly
ServeRAID adapter
216
Lenovo System x3630 M4 Installation and Service Guide
Summary of Contents for System x3630 M4
Page 1: ...Lenovo System x3630 M4 Installation and Service Guide Machine Type 7158 ...
Page 6: ...iv Lenovo System x3630 M4 Installation and Service Guide ...
Page 14: ...xii Lenovo System x3630 M4 Installation and Service Guide ...
Page 108: ...94 Lenovo System x3630 M4 Installation and Service Guide ...
Page 134: ...120 Lenovo System x3630 M4 Installation and Service Guide ...
Page 186: ...172 Lenovo System x3630 M4 Installation and Service Guide ...
Page 844: ...830 Lenovo System x3630 M4 Installation and Service Guide ...
Page 868: ...854 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1026: ...1012 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1030: ...1016 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1038: ...Taiwan BSMI RoHS declaration 1024 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1040: ...1026 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1049: ......
Page 1050: ......