Step 1.
Is the server part of a cluster?
•
No:
Go to Step 2.
•
Yes:
Shut down all failing servers that are related to the cluster. Go to Step 2.
Step 2.
Complete the following steps:
a.
Check the power supply LEDs (see “Power-supply LEDs” on page 24).
b.
Turn off the server and all external devices.
c.
Check all internal and external devices for compatibility at http://www.lenovo.com/
serverproven/.
d.
Check all cables and power cords.
e.
Set all display controls to the middle positions.
f.
Turn on all external devices.
g.
Turn on the server. If the server does not start, see “Troubleshooting by symptom” on page 141.
h.
Check the system-error LED on the operator information panel. If it is flashing, check the light
path diagnostics LEDs (see “Light path diagnostics” on page 127).
Note:
When you slide the light path diagnostics panel out of the server to check the LEDs
or checkpoint codes, do not run the server continuously with light path diagnostics panel
outside of the server. The panel should only be outside of the server a short time. The
light path diagnostics panel must remain in the server when the server is running to ensure
proper cooling.
i.
Check for the following results:
• Successful completion of POST (see “UEFI/POST” on page 138 for more information)
• Successful completion of startup, which is indicated by a readable display of the
operating-system desktop
Step 3.
Is there a readable image on the monitor screen?
•
No:
Find the failure symptom in “Troubleshooting by symptom” on page 141; if necessary, see
“Solving undetermined problems” on page 156.
•
Yes:
Run DSA (see “Running the DSA Preboot diagnostic programs” on page 139).
– If DSA reports an error, follow the instructions in Appendix C “DSA diagnostic test results” on
– If DSA does not report an error but you still suspect a problem, see “Solving undetermined
Diagnostic tools
The following tools are available to help you diagnose and solve hardware-related problems.
•
Light path diagnostics
Use light path diagnostics to diagnose system errors quickly. See “Light path diagnostics” on page 127
for more information.
•
Event logs
The event logs list the error codes and messages that are generated when an error is detected for the
subsystems IMM2, POST, DSA, and the server baseboard management controller. See “Event logs” on
page 135 for more information.
•
Integrated Management Module II
125
Summary of Contents for System x3630 M4
Page 1: ...Lenovo System x3630 M4 Installation and Service Guide Machine Type 7158 ...
Page 6: ...iv Lenovo System x3630 M4 Installation and Service Guide ...
Page 14: ...xii Lenovo System x3630 M4 Installation and Service Guide ...
Page 108: ...94 Lenovo System x3630 M4 Installation and Service Guide ...
Page 134: ...120 Lenovo System x3630 M4 Installation and Service Guide ...
Page 186: ...172 Lenovo System x3630 M4 Installation and Service Guide ...
Page 844: ...830 Lenovo System x3630 M4 Installation and Service Guide ...
Page 868: ...854 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1026: ...1012 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1030: ...1016 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1038: ...Taiwan BSMI RoHS declaration 1024 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1040: ...1026 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1049: ......
Page 1050: ......