1. Update the BMC firmware.
2. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
•
FQXSPUP4001I: Flash of [arg1] from [arg2] succeeded for user [arg3] .
This message is for the use case where a user has successfully flashed the firmware component (MC Main
Application, MC Boot ROM, BIOS, Diagnostics, System Power Backplane, Remote Expansion Enclosure
Power Backplane, Integrated System Management).
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0035
User Action:
Information only; no action is required.
•
FQXSPUP4002I: Flash of [arg1] from [arg2] failed for user [arg3].
This message is for the use case where a user has not flashed the firmware component from the interface
and IP address due to a failure.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0036
User Action:
Information only; no action is required.
•
FQXSPUP4003I: [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the
[arg3] firmware.
This message is for the use case where a specific type of firmware mismatch has been detected.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0042
User Action:
Complete the following steps until the problem is solved:
1. AC cycle the system.
2. Reflash XCC/BMC firmware to the latest version.
166
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference