2. Check Lenovo support site for an applicable service bulletin that applies to this Processor error.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFPU0007K: Processors have mismatched Internal DDR Frequency
Severity: Error
User Action:
Complete the following steps:
1. Verify that matching DIMMs are installed in the correct population sequence. Correct any
configuration issues found.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
•
FQXSFPU0008K: A core speed mismatch has been detected for one or more processors.
Severity: Error
User Action:
Complete the following steps:
1. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch
issues found.
2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
processor error.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFPU0009K: An external clock frequency mismatch has been detected for one or more
processors.
Severity: Error
User Action:
Complete the following steps:
1. Verify that the processor is a valid option that is listed as a Server Proven device for this system. If
not, remove the Processor and install one listed on the Server Proven website.
2. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch
found.
3. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
processor error.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFPU0010K: A cache size mismatch has been detected for one or more processors.
Severity: Error
User Action:
Complete the following steps:
1. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch
found.
.