Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0524
User Action:
Complete the following steps:
1. Please flash UEFI version to the latest level.
2. If the problem still exists, please remove and re-install the CMOS battery in 30 seconds to clear
CMOS contents.
3. If the problem still exists, please contact Lenovo support.
•
FQXSPCR2001I: Sensor [SensorElementName] has deasserted the transition to non-recoverable
from a less severe state.
This message is for the use case when an implementation has detected that the Sensor transition to non-
recoverable from less severe has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0525
User Action:
Information only; no action is required
•
FQXSPDA2000I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
•
FQXSPDM4000I: Inventory data changed for device [arg1], new device data hash=[arg2], new
master data hash=[arg3] .
Something has caused the physical inventory to change
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0072
70