FQXSPMA0009I: Memory sparing initiated for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
This message is for the use case when an implementation has detected that Memory double chip sparing
has been initiated.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0140
User Action:
Information only; no action is required.
•
FQXSPMA0010J: [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled.
This message is for the use case when an implementation has detected Memory has been Throttled.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0142
User Action:
Complete the following steps:
1. Check the event log of XClarity Controller for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the enclosure is not obstructed and that fillers are in
place, clean and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
•
FQXSPMA0011G: Memory Logging Limit Reached for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Warning - Memory
SNMP Trap ID: 43
CIM Prefix: PLAT CIM ID: 0144
User Action:
Complete the following steps:
1. If the compute node has recently been installed, moved, serviced, or upgraded, verify that the DIMM
is properly seated and visually verify that there is no foreign object in any DIMM connector on that
memory channel. If either of these conditions is found, correct and retry with the same DIMM. (Note:
The event Log might contain a recent FQXSFMA0011I event denoting a change is detected in DIMM
population that could cause this problem.)
92
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference