2. If the event persists, please consult with technical service.
•
086F0380: PSU 1: Power Supply, Power Supply input lost (AC/DC) was asserted.
The indicated power supply reports the input or line cord is lost.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141493120
User Action:
Information only; no action is required.
•
086F0381: PSU 2: Power Supply, Power Supply input lost (AC/DC) was asserted.
The indicated power supply reports the input or line cord is lost.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141493121
User Action:
Information only; no action is required.
•
086F0680: PSU 1: Power Supply, Configuration error was asserted.
The indicated power supply does not supported by this enclosure.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141493888
User Action:
1. Ensure the type of indicated power supply in the support list.
2. If the event persists, reseat the indicated power supply.
3. If the event persists, replace the indicated power supply. (Service technician only)
4. If the event persists, please consult with technical service.
•
086F0681: PSU 2: Power Supply, Configuration error was asserted.
The indicated power supply does not supported by this enclosure.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141493889
User Action:
1. Ensure the type of indicated power supply in the support list.
2. If the event persists, reseat the indicated power supply.
3. If the event persists, replace the indicated power supply. (Service technician only)
4. If the event persists, please consult with technical service.
•
106F0201: EvtLogDisabled: Event Logging Disabled, Log Area Reset/Cleared was asserted.
SMM2 system event log is cleared.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 275710465
User Action:
28
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference