Alert Category: PSU - Power Supply event
SNMP Trap ID: 141492680
User Action:
1. Check LED status of indicated power supply as
– If Input Power Good Indicator (IN) is not lit on, check power cord and input voltage of indicated
power supply.
– If Output Power Good Indicator (OUT) is not lit on, reseat indicated power supply.
– If Fault Indicator (!) is lit on, replace indicated power supply.
2. If the event persists, please consult with technical service.
•
086F01C9: PSU 2 OverTemper: Power Supply, Power Supply Failure detected was asserted.
The indicated power supply reports the internal sensing device reaches warning temperature and persists
over 30 seconds.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141492681
User Action:
1. Check LED status of indicated power supply as
– If Input Power Good Indicator (IN) is not lit on, check power cord and input voltage of indicated
power supply.
– If Output Power Good Indicator (OUT) is not lit on, reseat indicated power supply.
– If Fault Indicator (!) is lit on, replace indicated power supply.
2. If the event persists, please consult with technical service.
•
086F01D1: PSU 1 Fan Fault: Power Supply, Power Supply Failure detected was asserted.
The indicated power supply reports its fan 1 has fault condition.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141492689
User Action:
1. Check LED status of indicated power supply as
– If Input Power Good Indicator (IN) is not lit on, check power cord and input voltage of indicated
power supply.
– If Output Power Good Indicator (OUT) is not lit on, reseat indicated power supply.
– If Fault Indicator (!) is lit on, replace indicated power supply.
2. If the event persists, please consult with technical service.
•
086F01D2: PSU 2 Fan Fault: Power Supply, Power Supply Failure detected was asserted.
The indicated power supply reports its fan 1 has fault condition.
Severity: Error
Alert Category: PSU - Power Supply event
SNMP Trap ID: 141492690
User Action:
1. Check LED status of indicated power supply as
– If Input Power Good Indicator (IN) is not lit on, check power cord and input voltage of indicated
power supply.
– If Output Power Good Indicator (OUT) is not lit on, reseat indicated power supply.
– If Fault Indicator (!) is lit on, replace indicated power supply.
.
27