Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
•
FQXSFIO0010M: An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is
[arg6].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
a. Reseat Adapter and any attached cables.
b. Reload Device Driver.
c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
d. If a PCIe error has also been reported on a second slot within the same node, please ensure steps
a, b, and c above are also performed for that adapter before proceeding.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFIO0011M: A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function [arg3]. The
Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded.
a. Reseat Adapter and any attached cables.
b. Reload Device Driver.
c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
d. If a PCIe error has also been reported on a second slot within the same node, please ensure steps
a, b, and c above are also performed for that adapter before proceeding.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFIO0012M: A PCIe system error has occurred on Bus [arg1] Device [arg2] Function [arg3].
The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6].
.