![Leader Electronics Corp. LV 5330 Instruction Manual Download Page 148](http://html1.mh-extra.com/html/leader-electronics-corp/lv-5330/lv-5330_instruction-manual_1864727148.webp)
14. Status Display
14-24
• Selecting the Inter-Stationary Control Signal Format
To select the inter-stationary control signal format, follow the procedure below.
In the dump display, you can view the entire packet by scrolling through it with F•D.
Procedure
STATUS
→
F•4 ANC PACKET
→
F•3 V-ANC ARIB
→
F•2 NET-Q
→
F•1 DISPLAY
Settings
TEXT:
The packet is analyzed and displayed in text format. This is the default
setting.
DUMP:
The data for a single packet is shown using a dump display.
• Selecting the Dump Display Format
To select the dump display format, follow the procedure below.
This setting is valid when F•1 DISPLAY is set to DUMP.
Procedure
STATUS
→
F•4 ANC PACKET
→
F•3 V-ANC ARIB
→
F•2 NET-Q
→
F•2 DUMP MODE
Settings
HEX:
Data is displayed in hexadecimal format. This is the default setting.
BINARY:
Data is displayed in binary format.
DUMP MODE = HEX
DUMP MODE = BINARY
Figure 14-16 Dump display formats
• Turning Q Signals On and Off
To turn the displays for TRIGGER SIGNAL Q1 to Q32 on and off, follow the procedure
below.
This setting is valid when F•1 DISPLAY is set to TEXT.
Procedure
STATUS
→
F•4 ANC PACKET
→
F•3 V-ANC ARIB
→
F•2 NET-Q
→
F•6 next menu
→
F•1 Q1 to F•2 Q32
Settings
ON:
The specified Q signal is displayed. The default setting is 1.
OFF:
The specified Q signal is not displayed.