9
DESCRIPTION OF HART INTERFACE
82
OPTIWAVE 1010
www.krohne.com
10/2016 - 4003537403 - MA OPTIWAVE 1010 R03 en
Output, HART Dynamic
Vars
Primary
PV Value
Rd
/ PV Data Quality
Rd
/ PV Limit Status
Rd
Secondary
SV Value
Rd
/ SV Data Quality
Rd
/ SV Limit Status
Rd
Tertiary
TV Value
Rd
/ TV Data Quality
Rd
/ TV Limit Status
Rd
Current Output
PV % range
Rd
/ PV Loop current
Rd
Output (Chart)
Bar View
Level
Rd
/ Distance
Rd
/ Elect temp
Rd
/ Current
Rd
Scope View
Level
Rd
/ Distance
Rd
/ Elect temp
Rd
/ Current
Rd
Diag/Service
Status
Standard
Device status / Write protect
Device Specific
Device failures
device_specific_status_0
Rd
/
device_specific_status_1
Rd
Device Warning Maintenance
Required
device_specific_status_3
Rd
Device Warning Out of
Specification
device_specific_status_2
Rd
Info
device_specific_status_4
Rd
Test/reset
Loop test / Device reset / Reset Configuration Changed Flag
Spectrum view
Basic setup
Tag / Long Tag / PV is
Rd
/ PV (value)
Rd
/ PV (damping value)
Units
Length Unit / Elect temp unit
Range values
PV LRV
Rd
/ PV URV
Rd
/ Minimum Distance / Maximum Distance / Float Offset / Tube
internal diameter
Detailed setup
Sensors
Basic Param.
Minimum Distance / Maximum Distance / Float Offset / Float
Offset Calculation / Tube internal diameter
Application
Time constant / Tracing Velocity / Multiple Reflection
Service
1
Minimum Peak / Min. Plaus. Wind. / Offset / Corr. Factor / Device
Calibration
Output
Current Output
PV is
Rd
/ PV LRV
Rd
/ PV URV
Rd
/ PV Settings / Output Range /
Output Error Delay / Loop current mode / Loop test
Dynamic Variables
Mapping
SV is / TV is
Device Information
Manufacturer, Model
Manufacturer
Rd
/ Model
Rd
/ Firmware version
Rd
Identification
Descriptor / Message / Date / Final asmbly num / cfg chng
count
Rd
/ Software rev
Rd
/ Hardware rev
Rd
/ Snsr s/n
Rd
/ CPU
s/n
Rd
/ Elect. s/n
Rd
/ Elect. + Housing s/n
Rd
/ Sales Order Nber
Rd
Parameter Protection
Write protect
Rd
/ Access Level HART
Rd
/ Set Access Level /
Chge/Activ. Pwd
HART output
Identification
Poll addr / Tag / Long tag / Dev id
Rd
Preambles
Num req preams
Rd
/ Num resp preams
Rd
Revision
Universal rev
Rd
/ Fld dev rev
Rd
1
This menu is only available if the menu item "Set Access Level" is set to "Service". Go to Detailed Setup > Device Information > Param-