OPERATION
6
53
OPTIWAVE 1010
www.krohne.com
10/2016 - 4003537403 - MA OPTIWAVE 1010 R03 en
6.7.4 Basic parameters
Use the Basic parameters
Basic parameters
Basic parameters
Basic parameters menu to change how the device operates in the bypass chamber. The
supervisor can enter the data that follows:
CAUTION!
The device must be attached to a bypass chamber or magnetic level indicator to operate
correctly.
CAUTION!
The manufacturer enters the process conditions (density, type of product, operational
temperature and pressure) in the device settings at the factory. These data are given in the
customer order. Incorrect data will have an effect on the performance of the device.
(1) Minimum distance
(1) Minimum distance
(1) Minimum distance
(1) Minimum distance
This is the distance from the matching element to the
top point on the scale. The top point is the center of the
top process connection of the bypass chamber. This
value is set at the factory but you can change it on-site.
(2) Maximum distance
(2) Maximum distance
(2) Maximum distance
(2) Maximum distance
This is the distance from the matching element to the
bottom point on the scale. The end point is the center of
the bottom process connection of the bypass chamber.
This value is set at the factory but you can change it on-
site.
(3) Float offset
(3) Float offset
(3) Float offset
(3) Float offset
This value is set at the factory. If the device does not
measure the level of the product in the bypass chamber
correctly, it is possible that the product density used to
calculate the float offset is incorrect. If you make an
incorrect selection of the float, go to Application > Float
Application > Float
Application > Float
Application > Float
offset calculation
offset calculation
offset calculation
offset calculation in the DTM menu to calculate the new
float offset value For more data about this procedure,
refer to
Application on page 56.
(4) Tube internal diameter
(4) Tube internal diameter
(4) Tube internal diameter
(4) Tube internal diameter
This value is set at the factory and must not be changed.
Figure 6-15: Basic parameters menu