ELECTRICAL CONNECTIONS
4
27
OPTIWAVE 1010
www.krohne.com
10/2016 - 4003537403 - MA OPTIWAVE 1010 R03 en
Equipment needed:
•
Small slotted tip screwdriver (not supplied)
•
OPTIWAVE 1010 level transmitter attached to a BM 26 Advanced bypass level indicator
•
Ferrite choke. This part is supplied in a transparent plastic bag in the housing.
•
Electrical cable (not supplied)
Procedure
1
Remove the housing cover. Remove the transparent plastic bag and open it.
2
Put the electrical cable into the opening of the cable gland. Then put the electrical cable into
the opening of the ferrite choke.
3
Put the electrical wires in the connector terminals. Tighten the terminal screws with a small
slotted-tip screwdriver. Make sure that the electrical wires agree with the terminals.
4
Put the ferrite choke in the opening of the cable entry. Turn the ferrite choke until it is fully
engaged.
5
Tighten the cable gland. Attach the housing cover.
i
End of the procedure.
Procedure: Electrical connection and how to attach the ferrite choke to the electrical
cable
Figure 4-2: Procedure: Electrical connection and how to attach the ferrite choke to the electrical cable