SM-16007
3-67
TROUBLESHOOTING
Alarm
Code
Activation of Protection Device for Indoor Fan Motor
(Ducted (Medium Static and Slim) Type)
O
7KH581LQGLFDWRUUHGÀDVKHV
O
The indoor unit number (refrigerant cycle number - address number), the alarm code, the model code*
1)
,
the model name*
1)
and the number of connected indoor units are displayed on the LCD. The indoor unit
number and the alarm code are displayed on the 7-segment display of the outdoor unit PCB.
*1) Except for some models.
+
7KLVDODUPFRGHLVGLVSOD\HGZKHQWKHLQGRRUIDQPRWRUURWDWHVDWOHVVWKDQUSPIRU¿YHVHFRQGV
three times in 30 minutes during the operation.
Failure of I.U. PCB2
Failure of Fan Motor
Failure of I.U. PCB2
(*1)
Abnormal voltage is supplied
for fan motor.
Is LED1 on
I.U. PCB2 OFF?
(*1)
Check connectors PCN201
and CN201 on I.U. PCB2.
No
No
Yes
Does fan motor run?
Replace I.U. PCB2.
Replace Fan Motor.
Replace I.U. PCB2.
Replace Fan Motor
Yes
Yes
Occurrence of
Alarm Code “19”
(Normal Voltage: DC 280V)
Failure of Fan Motor
No
Check that 208/230V
is applied between
L1 and L2 of TB1.
NOTE:
Turn OFF the power source completely before
connector checking.
Otherwise, it may cause a DC fan motor failure.
(Built-in PCB for the DC fan motor may be damaged.)
Dose fan motor
meet decision basis
at “Checking for
Fan Motor”?
● Perform the following
check after setting the airflow
volume to “HIGH”.
● A high voltage is applied
to electrical parts.
Perform the check carefully
to prevent an electric shock.
Summary of Contents for YVAHP0721CW Series
Page 2: ......
Page 10: ...viii SM 16007 ...
Page 14: ......
Page 15: ...SM 16007 1 1 INSTALLATION 1 Installation ...
Page 163: ...SM 16007 2 1 OPERATION 2 Operation ...
Page 164: ...2 2 SM 16007 OPERATION Ɣ 5HIHU WR WKH 6HUYLFH 0DQXDO IRU QGRRU 8QLW RU RQWUROOHU ...
Page 165: ...SM 16007 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 284: ......
Page 285: ...SM 16007 4 1 MAINTENANCE 4 Maintenance ...
Page 360: ......
Page 390: ......
Page 391: ...SM 16007 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 400: ...6 10 SM 16007 FIELD WORK INSTRUCTIONS 0ROOLHU KDUW IRU 5 ft 3 l b ...
Page 401: ...SERVICE PARTS LIST SM 16007 7 1 7 Service Parts List ...
Page 416: ... 2016 Johnson Controls Inc SM 16007 Code No LIT 12012400 Issued November 2016 ...