Section 7: Programming Worksheets
Zone Attributes
068
Momentary
Keyswitch
Disarm
ü
069
Maintained
Keyswitch
Disarm
ü
071
Door Bell
ü
ü
072
Push to Set
ü
7.3 End Of Line Resistance
[004] End of Line Resistance description on
001 – Single EOL
Alarm (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 28 kΩ (005 to 280)
002 – Double EOL
Alarm (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 15 kΩ (005 -150)
Tamper (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 15 kΩ (005 -150)
003 –Triple EOL
Alarm (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 7.5 kΩ (005 -075)
Tamper (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 7.5 kΩ (005 -075)
7.4 System Times
[005] System Times description on
000 – System Area
Bell Cutoff (Default: 004 minutes):
(3-Digit Decimal)
Bell Delay Time (Default: 000 minutes):
Burglary Verification Timer (Default: 060 minutes):
Holdup Verification Timer (Default: 008 hours):
Zone Loop Response Time (Default: 025 x 10 ms):
Automatic Clock Adjust (Default: 060 seconds):
001 – Partition 1 Timer
Entry Delay 1 (Default: 030):
Entry Delay 2 (Default: 045):
Exit Delay (Default: 120):
Settle Delay (Default: 010):
002 – Partition 2 Timer
Entry Delay 1:
See partition 1 for defaults
Entry Delay 2:
Exit Delay:
Settle Delay:
003 – Partition 3 Timer
Entry Delay 1:
See partition 1 for defaults
Entry Delay 2:
Exit Delay:
Settle Delay:
- 173 -