Section 6: Programming
Note:
If no value is programmed and DHCP is used, the DHCP server will assign this value. If an address is programmed and DHCP
is used, the programmed address will be used instead of the DHCP address.
Programming Options
[010] System Toggle Options 3
[1] 2-Way Audio Over Cellular.
Default (OFF)
ON:
2-Way Audio Over Cellular is enabled.
OFF:
2-Way Audio Over Cellular is disabled.
[2] Visual verification.
Default (OFF)
ON:
Visual verification is enabled.
OFF:
Visual verification is disabled.
[3] Video On Demand.
Default (OFF)
ON:
Video On Demand is enabled.
OFF:
Video On Demand is disabled.
[4] Receiver Group.
Default (OFF)
ON:
Receiver Group is enabled.
OFF:
Receiver Group is disabled.
[5] Reserved.
[6] Reserved.
[7] Reserved.
[8] Reserved.
[011] Communicator Installer Code
Default (CAFE)
A communicator installer code is required to program the communicator module. Valid range: 0000-FFFF.
[012] DLS Incoming Port
Default (03062)
The DLS incoming local port (listening port) is the port DLS IV uses when connecting to the communicator. If a router or gateway is
used, it must be programmed with a transmission control protocol (TCP) port forward for this port to the communicator module IP
address. Valid range: 00000 - 65535.
[013] DLS Outgoing Port
Default (03066)
The DLS outgoing port is used for outgoing sessions to DLS IV after an SMS request has been sent to the communicator. Use this
section to set the value of the local outgoing port. The value must be changed if the communicator is located behind a firewall and
must be assigned a particular port number, as determined by the network administrator. In most cases, changing the default value or
configuring the firewall with this port is not required.
Valid range: 00000-65535.
Note:
If section [006] toggle option [7] is ON, DLS will use the primary path for session. If section [006] toggle option [7] is OFF, DLS
will use the Ethernet path, if available.
[015] DLS Call-Up IP
Default (000.000.000.000)
[016] DLS Call-Up Port
Default (00000)
Valid range: 00000-65535.
[018] Receiver Group Pair
Use
Receiver Group Pair
to send visual verification signals to multiple central station receivers, or when the product is installed in
ULC applications. The communicator retransmits signals to the individual receivers if there is a communications problem, and
indicates an FTC on the control panel if there is an error in either of the communication paths. The system keypad displays
Receiver
X FTC Trouble
.
You can assign any two receiver paths to the receiver group, but using Ethernet Receiver 1 and Cellular Receiver 1 in this
configuration ensures a single point of failure does not disable both alarm reporting paths.