Section 6: Programming
[018] System Option 6
1 – Test Transmission Exception
ON: The alarm system does not send a test transmission if a transmission was sent to the receiver within the programmed interval as
set in section [377]>
See "[003] – Periodic Test Transmission Cycle" on page 132
.
OFF: Test transmissions are always sent at the programmed interval.
2 – Real-Time Bypass Reporting
ON: When a non-24-hour zone is bypassed in [*][1], the system immediately logs and communicates the bypass status of the zone.
Global Zones: 24-hour and non-24 hour zone bypasses are logged and communicated in real time. Non-24 hour zone unbypass
events are generated when the last assigned partition is disarmed.
OFF: When a non 24-hour zone is bypassed in [*][1], the system logs and communicates the bypass status of the zone only after the
partition is armed. This option is applied regardless of how zones are bypassed in [*][1], recall bypass group, clear all bypasses,
bypass open zones, bypass recall as well as other methods such as bypassing via ITv2 or DLS.
Global Zones: 24-hour zone bypasses are logged and communicated in real time. Non 24-hour zone bypass events are logged and
communicated when armed. Non 24-hour zone unbypass events are logged and communicated when the partition is disarmed.
3 – Armed Status PGM ON at End of Exit Delay
ON: PGMs are activated at the end of exit delay. This applies to PGMs with one of the following armed status attributes:
l
115 System Armed Status PGM
l
116 Away Armed Status PGM
l
117 Stay Armed Status PGM
l
120 Away Armed with No Zone Bypass Status
l
129 Partition Status Alarm Memory
OFF: PGMs are activated at the beginning of exit delay. This applies to PGMs with one of the armed status attributes listed above.
4 – Auto Bypass Report
ON: All Night or Stay/Away type zones that are auto-bypassed when arming in Night or Stay mode log and report Zone Bypass. When
disarming, all auto-bypassed Night or Stay/Away zones log and report Zone Un-Bypassed. All manually bypassed zones continue to
log and report.
OFF: All Night or Stay/Away type zones that are auto-bypassed when arming in Night or Stay mode do not log or report Zone Bypass.
When disarming, all auto-bypassed Night or Stay/Away zones do not log and report Zone Un-Bypassed. All manually bypassed
zones continue to log and report.
5 – Keypad Buzzer Follows Bell
ON: The keypad buzzer activates with all bell activity for the selected partition.
OFF: The keypad buzzer only activates with alarms programmed to do so.
7 – Exit Delay Restart
ON: Opening a delay zone door after it has already been opened and closed during an exit delay restarts the exit delay timer. Further
openings and closings do not restart the timer.
OFF: Delay zone openings and closings do not restart the exit delay.
8 – AC Fail Trouble Beeps
ON: System keypads beep when an AC trouble event occurs.
OFF: System keypads are silent during AC troubles.
6 – Reserved
[019] System Option 7
1 – Audible Wireless Device Fault
ON: If a wireless zone fault occurs while armed, the siren sounds for the duration of Bell Time Out. This option only affects zone
definitions that are considered armed. The following zone types do not generate an alarm when faulted while stay armed: interior stay
away zone, delay stay away zone, instant stay away zone, night zone. The following zone types do not generate an audible alarm in
any armed state (stay, away, or night): 24-hour supervisory, 24-hour non-alarm, 24-hour CO, delayed 24-hour Fire, standard 24-hour
fire, Auto-verified fire.
When the partition is armed, wireless supervisory troubles from sirens, keypads and repeaters generate audible alarm conditions.
If Tamper/Fault Detection is enabled, these events can start the burglary verified timer and affect the burglary verified counter.