Section 5: System operation
5.4 Annunciation
Door chime
The keypad can be programmed to use one of four different door chime tones for each zone on the system. Chime is active only
during the disarm state. Only one door chime option can be enabled for each zone.
l
Beeps
l
Bing-Bong
l
Ding-Dong
l
Alarm Tone
l
Zone Name - Voice annunciation (HS2LCDWFVPROx keypads only)
The above door chime sounds are programmable in section [861]-[892], subsections [101]-[228].
Chime is enabled/disabled on a partition using the [*][4] command.
Temperature display
Indoor and outdoor temperature can be displayed on system keypads if configured in keypad programming section [861]-[892]>[023]
option 7, and sections [041]-[042]. Temperature is detected using wireless temperature sensors installed on the system.
"Compatible devices" on page 8.
Note:
Global keypads only display outdoor temperature.
Low temperature warning
Keypads can be configured to detect low ambient temperature.
If the temperature at the keypad drops to 6° C ± 2° C (43° F ± 3°F), the keypad zone goes into alarm. When the temperature rises
above 9° C ± 2° C (48° F ± 3° F), the keypad zone is restored.
When this option is enabled, the keypad’s zone input functionality is disabled.
Refer to section [861]-[892]>[023] option 8 for more information.
Note:
This feature has not been evaluated by UL/ULC.
5.5 Keypad function keys
Keypads have five programmable function keys that can be configured to perform one of the following actions:
Table 5-2: Function key programming options
Function key
Description
Function key
Description
[00]
Null function key
[17]
Arm interior
[02]
Instant stay arm
[21]-[24]
Command output 1 to 4[*][71] - [*][74]
[03]
Stay arm
[29]
Bypass group recall
[04]
Away arm
[31]
Local PGM activate
[05]
[*][9] No entry arm
[32]
Bypass mode
[06]
[*][4] Chime on/off
[33]
Bypass recall
[07]
System test
[34]
User programming [*][5]
[09]
Night arm
[35]
User functions [*][6]
[12]
Global stay arm
[37]
Time & date program
[13]
Global away arm
[39]
Trouble display [*][2]
[14]
Global disarming
[40]
Alarm memory [*][3]
[15]
Temperature
[61]-[92]
Partition 1 to 32 select
[16]
Quick exit
To program a function key:
1. Enter Installer Programming [*][8].
2. Enter section [861] for keypad 1 function key programming.
3. Enter [001] to [005] to select a function key to program.
4. Enter a 2-digit number to assign a function key operation - [00] - [92]. See table above.
5. Continue from step 3 until all function keys are programmed.
6. Press the [#] key twice to exit Installer Programming.