Section 5: System operation
Note:
Programmed function keys must be pressed for 2 seconds in order to activate the function.
Function key definitions
This section provides detailed descriptions of each programmable function key option.
[00] Null function key
This option deactivates the function key. The key does not perform any function when pressed.
[02] Instant stay arm
This feature is similar to the Stay Arm function key, except that no exit delay is applied and the system arms immediately.
If no Stay/Away zone types are programmed, the alarm system arms in Away mode.
Note:
Do not use this function with CP-01 installations.
[03] Stay arm
Only perimeter zones are armed. Interior zones are bypassed regardless of whether or not delay zones are tripped during the exit
delay.
[04] Away arm
All interior and perimeter zones are armed. CP-01 panels require an exit through a delay zone during the exit delay or the system will
arm the perimeter zones only.
[05] No entry arm [*][9]
All Delay 1 and Delay 2 zones become instant zones. If a door or window is opened the system goes immediately into alarm. This
function is typically used when no occupants are expected to return to the site during the armed period. Activation of this function key
requires an access code. This function only works while the system is disarmed.
See "[*][9] No-entry arming" on page 79
for more information.
[06] Chime on/off
This function turns the door chime on or off and is the equivalent of pressing [*][4]. The alarm system must be disarmed to use this
function. If option 7 in section [023] is enabled, this function key requires an access code.
[07] System test
This function performs a system test when pressed and is the equivalent of entering [*][6][Access Code][04]. The alarm system must
be disarmed to use this function.
See "[*][6] User functions" on page 76
for more information.
[09] Night arm
All perimeter and interior zones, excluding Night zones, are armed. This key only works while the system is disarmed or armed in
Stay mode.
If no Night type zones are programmed, the alarm system arms in Away mode with an audible exit delay. Exit delay is silent.
Arming in this mode activates the Away Arming PGM output.
[12] Global stay arm
This function arms all partitions assigned to the user in Stay mode, provided they are ready to arm. If a partition is not ready, the
system cannot be armed. An access code is required with this option.
[13] Global away arm
This function arms all partitions assigned to the user in Away mode, provided they are ready to arm. If a partition is not ready, the
system cannot be armed. An access code is required with this option.
[14] Global disarming
This function disarms all partitions assigned to the user. An access code is required with this option.
[15] Temperature
This function allows the keypad to directly access the temperature display menu.
[16] Quick exit
Pushing this key gives the user a 2 minute window to open and close one delay zone once without having to disarm the system. This
function is equivalent to entering [*][0] at the keypad while the partition is armed. If quick exit is not enabled on the system, or if the
- 64 -