Appendix 5: Regulatory approvals
l
The bell timeout shall be programmed for 15 minutes minimum.
l
At least one system remote keypad with tamper switch shall be employed
l
The integral communciator (DACT/IP) or plug-in cellular module shall be enabled and shall be programmed to provide a low
battery transmission.
l
The control panel shall be in a separately listed HSC3030CAR attack resistant enclosure.
l
The maximum entry delay time shall not exceed 45s (25s for a local) as a result of the attack test. The maximum exit delay
time shall not exceed 60 s.
l
A tamper switch shall be used to protect the enclosure cover of the control unit. A tamper switch shall also be used on the
keypad rear to detect removal from the wall.
l
24 h check in transmission shall be enabled.
l
Open/Closing acknowledgement enabled.(Not Police Station).
l
The Installation shall use the internal communicator (DACT or IP) alone or in conjunction with plug-in cellular modules Models
LE9080, 3G9080 or 3H9080, which communicate over Cellular Data Network or an Ethernet network 10/100BaseT to the
compatible Sur-Gard System I/II/III/IV/5 receiver.
UL Home Health Care Signaling Equipment
l
There must be at least two keypads, one of the compatible keyapds models HS2LCDPRO, HS2LCDRFPRO9,
HS2LCDWFPRO9, HS2LCDWFVPRO9, HS2TCHPRO(BLK).
l
Each system shall be programmed to activate an audible Trouble signal within 90 seconds upon loss of microprocessor
memory
ULC Central Station Fire and Burglary Monitoring Installations
l
For installation requirements, levels of security, communication modules and configurations (Refer to the ULC Installation
Guide for PowerSeries Pro, P/N #29010346).
l
HS2TCHPRO(BLK) touch screen keypad is for supplementary use only with ULC Commercial Fire Monitoring.
l
For Commercial Fire monitoring, the primary power failure transmission may be delayed up to 3h and Bell shall be disabled.
Note:
As per ULC Bulletin 2017-02A, ULC Fire and Security Systems Group is accepting the use of MFVN digital telephone services
for connection of digital dialer transmitters ULC listed to be connected to the public switched telephone network communication
system. Since the MFVN communication channel technologies available are not provided with 24 hour standby power on the
equipment and facilities used between the premises and the signal receiving center, it is required that, for passive communication
channels used in monitored protective signaling system installations, the testing time of the passive communication channels should
be reduced from the current 24 hours to 6 hours to better ensure that the system and communication channels are operating in their
intended manner to reduce the life safety risk. A change in testing frequency for intrusion alarm systems is not required due to the
many different levels of line security options available for these system types, which should be applied based on communication
supervision needs for each installation.
For PowerSeries Pro panels, the following programming options shall be adjusted to meet the new 6 hour test transmission when
used in ULC-S561 compliant installations:
l
Section [022] turn option 4 ON for hours.
l
Section [377] option [003] set to 006 (for 6 hours).
l
Section [309] option [002] enable test transmission for all applicable receivers.
Programming
The notes in the programming sections of thePowerSeries Pro Reference Manual describing the system configurations for UL/ULC
listed installations shall be implemented.
Control of the Protected Premises
In order to have a UL certificated system, the protected area shall be under the responsibility of one ownership and management (i.e.,
one business under one name). This may be a group of buildings attached or unattached with different addresses but under the
responsibility of someone having mutual interest. The person of mutual interest is not the alarm-installing company.
Note:
This does not apply to strip mall applications where each independent business must have their own separate alarm system.
e.g.,1: A commercial partitioned system that has an office and a warehouse area in a building where each area can be armed or
disarmed independently. e.g.,2: A residential system partitioned so that the garage area is armed separately from the house.
Each of the above examples is under the sole responsibility of a single owner. The bell and DACT power supply must be in a
protected area including partitioned systems. The bell and DACT power supply must be located where it can be heard by the person
or persons responsible for maintaining the security system during the daily arming cycle.