Section 6: Programming
l
DLS Access Code: The 6-digit DLS access code used in programming section [403].
l
Partition 1 Entry Delay: The 3-digit entry delay duration for partition 1, in seconds, used in programming [005][001] option 1.
l
Partition 1 Exit Delay: The 3-digit exit delay duration for partition 1, in seconds, used in programming section [005][001] option
3.
l
Installer Code: The 4, 6 or 8-digit installer access code used in programming section [006][001].
For more information on template programming, see
Systems Information
[900] System Information
[000] – Control Panel Version
This read-only section contains the model number, software version, hardware revision and serial number of the alarm controller. For
example, an entry of 1234 is read as version 12.34.
[001]-[524] – Module Information
This read-only section is used to view the model number, software version, and hardware revision information of the modules
enrolled on the alarm system.
To view information for a specific module, scroll to the corresponding section:
[001]-[032] Keypads
[101]-[130] 8-zone expansion module
[201]-[216] 8-output expansion module
[301] -[330] 8 zone expansion module
[460] Alternate communicator
[461] HSM2Host module
[481] 2 Way Audio Module
[501]-[504] 1A power supply module
[521]-[524] High-current output modules 1-4
[551]-[554] 3A power supply
[601]-[616] Corbus repeater
[901] Installer Walk Test Mode Enable/Disable
This mode tests the operation of each detector in the system. Enter section [901] to initiate a walk test. While in Walk Test mode, the
Ready, Armed, and Trouble LED's on the keypad flash to indicate that the test is active. When a zone is tripped during the test, a 2-
second tone sounds on all system keypads to indicate that the zone is working correctly.
After 10 minutes without zone activity, the alarm system emits 5 beeps every 10 seconds from all keypads. After another 5 minutes of
inactivity, Walk Test terminates automatically.
To manually exit walk test mode, enter [901] again.
Module Programming
Use this section to add, remove and confirm the following modules:
l
Keypads see
l
8-zone expander module (HSM2108)
l
8-output expander module (HSM2208)
l
Power supply (HSM2300)
l
4-output power supply (HSM2204)
l
Wireless transceiver (HSM2HOSTx)
l
Audio Verification Module (HSM2955)
l
8 zone Expansion Module (HSM3408)
l
Power Supply Module (HSM3350)
l
Corbus Repeater Module (HSM3204CX)
Once added, modules are supervised by the system.
[902] Add/Remove Modules
Modules can be enrolled automatically our manually. In either case, the serial number of the device is used as an identifier.
Select one of the enrollment options described below.
- 156 -