Section 6: Programming
Receiver 2 uses the same format programmed for Receiver 1.
OFF: Receiver 2 is independent and will communicate if a number and format are programmed.
3 – Receiver 3 Backup Option
ON: Receiver 3 backs up Receiver 2. Receiver 3 is only used if an FTC event is detected on Receiver 2.
Receiver 3 uses the same format programmed for Receiver 2.
OFF: Receiver 3 is independent and will communicate if a number and format are programmed.
4 – Receiver 4 Backup Option
ON: Receiver 4 backs up Receiver 3. Receiver 4 is only used if an FTC event is detected on Receiver 3.
Receiver 4 uses the same format programmed for Receiver 3.
OFF: Receiver 4 is independent and will communicate if a number and format are programmed.
[385] Audio Module Talk\Listen Mask
1- Talk/Listen on Receiver 1
ON: 2-way audio sessions can be initiated over receiver 1.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over receiver 1.
2- Talk/Listen on Receiver 2
ON: 2-way audio sessions can be initiated over receiver 2.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over receiver 2.
3-Talk/Listen on Receiver 3
ON: 2-way audio sessions can be initiated over receiver 3.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over receiver 3.
4-Talk/Listen on Receiver 4
ON: 2-way audio sessions can be initiated over receiver 4.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over receiver 4.
DLS Programming
Downloading allows programming of the entire alarm system via a computer. All functions and features, changes and status, such as
trouble conditions and open zones, can be viewed or programmed by downloading.
The following downloading options are available:
l
6-hour window on start up: When the alarm system is powered up, downloading access is available for 6 hours. This provides
the option of downloading without having to complete any keypad programming.
l
Double call method: The installer initiates a downloading window by calling the alarm system, hanging up, then calling back
again.
l
User enabled DLS window: The user initiates a downloading window using [*][6][Master code][05]. This can be a 6-hour
window where the installer initiates and terminates downloading as many times as necessary, or it can be a 1-hour, 1 use
window.
l
User initiated call-up: the user can initiate a downloading session using [*][6][Master Code][06].
l
On-site downloading using USB: The installer connects a computer directly to the alarm system to perform on-site
downloading.
l
Auto event buffer upload: The Event buffer is automatically uploaded to the DLS/SA computer when it reaches 75% full.
Refer to the DLS/SA programming sections described below for configuration options.
[401] DLS/SA Options
1 – Double Call
ON: Calls for downloading or SA are answered if a successful double call routine is detected. Have the downloading computer call
the system and let the telephone line ring once or twice. After 1 or 2 rings, hang up. If called back within the duration of the double call
timer (section [405]), the alarm system answers on the first ring.
OFF : Incoming calls are not answered using the double call routine unless the user enables the DLS window.
Note:
This feature controls the DLS window for PSTN connections only.
2 – User Enables/Disables DLS
ON : The [*][6][Master Code][05] command enables a 6-hour window where, on power-up, downloading calls are answered if a
successful double call routine is detected.