Appendix 5: Regulatory approvals
Table 5-1: SIA quick reference
SIA Feature Programming
Section
Comments
Range/Default Requirement
Exit Time
[005]>[001], option 3
Access to Entry and Exit delays and Bell Time Out for the
system.
Range:45- 255
seconds
Default: 60 sec.
Required
(programmable)
Exit Delay Restart
[018], option 7
Opening a Delay zone door after it has already been opened
and closed during an exit delay restarts the exit delay timer.
Default:
Enabled
Required
Auto Stay Arm on Un-vacated
Premises
[001]>[001]-[248] Zone type 05,
06,09
Function key: Forces the system to arm in Stay mode if the
occupant does not exit the premises after pressing the Away
function key.
If no exit after
full arm
Default:
Enabled
Required
Exit Time and Progress
Annunciation/Disable or Remote
Arming
[861]>[001]-[005], option 4
System times and audible exit beeps can be disabled when
using the wireless key to stay arm the system. When away
arming, audible exit beeps can not be disabled.
For remote arming (using keyfob), it is possible to program the
instant stay arm (no exit delay). By default this option is OFF.
When arming/disarming with keyfob the bell squawk option
shall be enabled.
The Bell shall be tested daily. Alternate option is to have bell
squawk enabled for arming/disarming
Default:
Enabled
Allowed
Entry delay(s)
[005]>[001]-[008], options 1 and 2
Access to entry and exit delays and bell time out for the
system
Note: Combined entry delay and communications delay (abort
window) shall not exceed 60s.
Range: 30 sec.
to 4 min.
Default: 30 sec.
Required
(programmable)
Abort Window for Non-Fire zones
[002]>[001]-[248], option 7 ON
Access to zone attributes, i.e., swinger shutdown,
transmission delay and cross zone. May be disabled by zone
or zone type.
Default:
Enabled
Required
Abort Window Time - for Non-Fire
zones
[377]>[002], option 1
Access to the programmable delay before communicating
alarms
Note: Combined entry delay and communications delay (abort
window) shall not exceed 60 seconds.
Range: 00 - 45
sec.
Default: 30
sees
Required
(programmable)
Abort Annunciation
An audible tone is generated when an alarm is aborted during
the abort window.
Hard-coded
ON
Required
Duress Feature
[*][5]> master code> user 2-95> 5>
2
When this feature is enabled, selected user codes send a
duress reporting code to the central station when used to
perform any function on the system. Section [019], option [6]
must be enabled.
Default: N
Required
Cancel Window
[377]>[002], option 6
Access to the communications cancel window. Minimum
duration must be 5 minutes.
Range: 005-
255
Default: 005
Cancel Annunciation
[308]>[001], option 8
Access to the reporting code for Alarm Canceled.
A Cancel was
transmitted
Default:
Enabled
Required
- 310 -