Section 6: Programming
[313] Maintenance Events 3
1/2 – Firmware Update Begin/was Successful
Sent when a remote firmware update is initiated/ is successfully completed.
3 – Firmware Update Fail
Sent after an unsuccessful remote firmware update.
[314] Maintenance Events 4
1/2 – Gas Trouble/Restore
Sent when a trouble occurs or is restored on a wireless gas detector.
3/4 – Heat Trouble/Restore
Sent when a heat trouble occurs or is restored on a wireless temperature detector.
5/6 – Freeze Trouble/Restore
Sent when a freeze trouble occurs or is restored on a wireless temperature detector.
7/8 – Probe Disconnected Trouble/Restore
Sent when a probe disconnected trouble occurs or is restored on a wireless temperature detector.
[321] Receiver Events
2/4/6/8 – Receiver 1 - 4 FTC Restore
Sent when the panel detects an FTC trouble.
[331] Module Events 1
1/2 – Module AC Trouble/Restore
This reporting code is transmitted when a module’s AC supply fails or has been restored. A programmable delay applies to both the
trouble and the restore. This reporting code is sent to the System Maintenance call direction group.
3/4 – Module Battery Trouble/Restore
These reporting codes are transmitted when a module’s battery voltage falls below 11.5VDC or is restored. These reporting codes
are sent to the System Maintenance call direction group.
5/6 – Module Battery Absent/Restore
These reporting codes are transmitted when a module’s battery is absent or is restored. These reporting codes are sent to the System
Maintenance call direction group.
7/8 – Module Power Unit Failure/Restore
These reporting codes are transmitted when a module’s battery is detected as absent or restored. These reporting codes are sent to
the System Maintenance call direction group.
[332] Module Events 2
1/2 – Module Low Voltage Trouble/Restore
Sent when module voltage drops below acceptable levels or is restored.
3/4 – Module Supervisory Trouble/Restore
Sent when communication with a module is lost or restored.
5/6 – Module Aux Trouble/Restore
Sent when a high current output module or power supply module experiences an auxiliary voltage supply trouble.
[335] Module Events 5
1/2 – Output 1 Fault/Restore
This reporting code is sent when the first output on the high-current output expander module goes into fault (open or short) or is
restored.
Only the first output on the high-current expander module is supervised.
[351] Alternate Communicator 1
1/2 – Alt. Comm Communications Fault/Restore
Sent when the system loses or restores communications with the alternate communicator.
- 128 -