Section 6: Programming
14 – Hold Up Verification
ON: An alarm from zones of this type can contribute to a verified hold up alarm. Use this attribute with Panic and Hold Up zones.
OFF: An alarm from zones of this type does not contribute to a verified hold up alarm. The zone does not cause the hold up
verification timer to start counting down, or generate a verified hold up if the alarm is detected while the timer is running.
15 - Triple EOL
ON: The zone requires triple-end-of-line resistors.
OFF: The zone follows programming in section [013] option 2.
EOL resistance
This section describes how to program EOL resistances to custom values.
[004] End of line resistance
Use this menu to program custom resistance values for SEOL, DEOL, and TEOL options in 3-digit format. For example, to program
the value of 0.5 kΩ, enter 005.
[001] – Single EOL
Alarm
Default value: 5.6 kΩ
Programmable range: 0.5 kΩ to 28 kΩ (005 to 280)
[002] – Double EOL
Alarm
Default value: 5.6 kΩ
Programmable range: 0.5 kΩ to 15 kΩ (005 to 150)
Tamper
Default value: 5.6 kΩ
Programmable range: 0.5 kΩ to 15 kΩ (005 to 150)
[003] – Triple EOL
Alarm
Default value: 5.6 kΩ
Programmable range: 0.5 kΩ to 7.5 kΩ (005 to 075)
Tamper
Default value: 5.6 kΩ
Programmable range: 0.5 kΩ to 7.5 kΩ (005 to 075)
Fault/Mask
Default value: 10 kΩ
Programmable range: 0.5 kΩ to 15 kΩ (005 to150)
System times
This section describes how to program various timers applicable to the entire alarm system.
[005] System times
This is the base menu used by installers to program timers, including system area [000], partition timers [001]-[032], and daylight
saving time [901]/[902].
[000] – System Area
Bell Cutoff Time
System sirens follow the programming for this timer. Fire alarms follow this timer if section [014] option 8 (Fire Bell Continues Option)
is off. System tampers follow this timer. The bell cutoff time is programmed in minutes. Valid entries are 001 to 255 minutes.
Note:
Keypad buzzer alarms do not follow this timer.
Bell Delay Time
The Bell Delay Timer determines how long the bell will be delayed after a zone alarm event. Valid entries are 000-255 where 000
disables this feature.
- 93 -