Chapter 4: Commands for CLI configuration
<EceId : 1-4096>
ECE identifier
direction
Setup ECE direction
both
Bidirectional traffic flow
nni-to-uni
NNI-to-UNI traffic flow
uni-to-nni
UNI-to-NNI traffic flow
evc
EVC mapping
<EvcId : 1-4096>
EVC identifier
none
Map to no EVC ID
frame-type
Setup matched frame type
any
Match any frame type
ipv4
Match IPv4 frames
ipv6
Match IPv6 frames
inner-tag
Setup inner tag options
add
Setup inner tag add properties
.
dei
Setup added tag DEI
<AddDei : 0-1>
Added tag DEI
pcp
Setup added tag PCP
<AddPcp : 0-7>
Added tag PCP
preserve
Setup tag PCP/DEI preservation
type
Setup added tag type
c-tag
Add C-tag
none
No tag added
s-custom-tag
Add custom S-tag
s-tag
Add S-tag
vid
Setup added tag VLAN ID
<AddVid : vlan_id>
Added tag VLAN ID
match
Setup inner tag match properties
dei
Setup matched DEI
<MatchDei : 0-1>
Matched DEI
any
Match any DEI
pcp
Setup matched PCP
<MatchPcp : pcp>
Matched PCP value/range
any
Match any PCP
type
Setup matched tag type
any
Match tagged and untagged frames
c-tagged
Match C-tagged frames
s-tagged
Match S-tagged frames
tagged
Match tagged frames
untagged
Match untagged frames
vid
Setup matched VLAN ID
<Vid : 0-4095>
Matched VLAN ID value/range
any
Match any VLAN ID
interface
Setup UNI
next
Setup the ECE ID of the next entry
<EceId : 1-4096>
Select ECE ID of an existing entry
52
NS3500-24T-4C Managed Switch Command Guide