Chapter 4: Commands for CLI configuration
Example:
To display the
ERPS group 1
detailed information.
Switch #
show erps 1 detail
Grp# Port 0 Port 1 RPL:Role Port Blocking
1 Gi 1/1 Gi 1/2 - - -
Protected VLANS:
None
Protection Group State :Active
Port 0 SF MEP :1
Port 1 SF MEP :2
Port 0 APS MEP :1
Port 1 APS MEP :2
WTR Timeout :1
WTB Timeout :5500
Hold-Off Timeout :0
Guard Timeout :500
Node Type :Major
Reversion :Revertive
Version :2
ERPSv2 Administrative Command :None
FSM State :PENDING
Port 0 Link Status :Link Up
Port 1 Link Status :Link Up
Port 0 Block Status :BLOCKED
Port 1 Block Status :BLOCKED
R-APS Transmission :STOPPED
R-APS Port 0 Reception :NONE
R-APS Port 1 Reception :NONE
FOP Alarm :OFF
show evc
Command:
show evc { [ <evc_id> | all ] } [ ece [ <ece_id> ] ]
show
Show running system information
evc
Ethernet Virtual Connections
<EvcId : 1-4096>
EVC identifier
all
Process all EVCs
ece
EVC Control Entry
<EceId : 1-4096>
ECE idenfifier
Default:
N/A
Usage Guide:
To display the
EVC status
.
Example:
To display the All of
EVC status
.
NS3500-24T-4C Managed Switch Command Guide
261